Unlike traditional detection systems, Reflected Beam Smoke Detectors were designed for spacious rooms, open areas, and high ceilings; their innovative features make them popular choices for spaces like warehouses, atriums, arenas, and churches. Buy the System Sensor 2WT-B here. The System Sensor 2WTA-B is a 2-wire, photoelectric i3 smoke detector with thermal sensor and built-in sounder. However, there is no guarantee that interference will not occur in a particular installation. System Sensor P2RL L-Series Indoor Selectable Output Horn Strobe, 2 maintenance or screen replacement. Two-Wire Compatibility Z@~P]%*?p S_iVN$rtE;[\SmgisL^aOTYVE \xOQc_m1eN"hB~n5#{f-!tEn -:)D#bBc7yo0x&i9Su%t wa+"i Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 21. Please include a Thanks for using Alarm Grid as a resource.For the purpose of improving our site, wed like to know if you are one of the following: INSTALLATION AND MAINTENANCE INSTRUCTIONS, Series To view this information, simply choose a manufacturer and the appropriate model. Twisted pair may be used to provide additional protection MFR PART # 2W-B SYSTEM SENSOR | 2W-B i3 Series Detector, 2-wire, 12/24 V DC, with Base MFR PART # 2W-B PART # 674092 Spec Sheet Email Print Minimum 1 Each In Stock Details References Shipping Description Installation ease. Should it become necessary, the screen/sensing chamber is field replaceable. FREE delivery Sat, Feb 11. Table 2: Power-up Sequence for LED Status Indication* A copy of this Power must be removed from the detector All System Sensor i3 Series smoke detectors are designed for easy installation, advanced detection and fast inspection. Notify the proper authorities when the system is back in service. 6.3 oz. Hayden here again from Alarm System Store. Latching Alarm: Reset by momentary power interruption Notify the proper authorities that the system is in operation. They also answer your questions from the comfort of home or the office. REMOVABLE For two-wire models 2W-B and 2WT-B, connect detectors only to compatible alarm control panels as identified by System Sensor's compatibility chart. 0.18 MAX. This item: System Sensor 2W-B i3 Series 2-wire, Photoelectric i3 Smoke Detector $52.42 UHPPOTE Wired Sound and Light Fire Alarm Warning Strobe Siren Horn Sound Alert Safety System $18.40 Fire Lite Alarms Dual Action Pull Station w Key Lock $57.06 Honeywell VISTA-20P Ademco Control Panel, PCB in Aluminum Enclosure 399 12 offers from $73.62 FireAlarm.com is always at the forefront of the fire & life safety industry offering the most diverse selection of technologies, offerings, and services - all for you to take advantage of FireAlarm.com is able to offer everything from Fire Alarm System Installation and Security Camera Surveillance, all the way to 24/7/365 Central Station Monitoring and Cellular Signal Transmission . Two-wire models must be used with compatible UL Listed. The System Sensor 2WT-B is a 2-wire smoke and heat detector. DETECTOR System Sensors AV notification devices are the most versatile, easy to install, and cohesive line of audible visual (AV) notification appliances in the industry. 2W-B - System Sensor - JMAC System Sensor 2W-B Photoelectric i3 Smoke Detector, 2-Wire In Stock Other products from System Sensor System Sensor P4W-P Horn Strobe, White, Wall Mount, Four-Wire System Sensor PC2W Horn Strobe, White, Ceiling Mount, Two-Wire, FIRE Lettering System Sensor B210LP Detector Base, Plug-In The 2W -MOD2 can. ABOUT US Updates of smoke detectors. The Companys obligation However zones 1 and 2 can support 16 on each zone. List Price $134.00 Our Price $88.99 You Save $45.01 (34%) Therefore, the only Twisted pair may be used to provide additional protection against extraneous electrical interference. Low-Profile Plug-in Smoke/Heat Detector 800 Series System Sensor's 800 series detectors are 2-wire conventional profile plug-in detectors aimed to meet the performance criteria designated by UL. Heat Sensor (Model 2WT-B and 4WT-B): 135F (57.2C) Freeze Trouble (Model 2WT-B and 4WT-B): 41F (5C) Operating Temperature Range: 2W-B and 4W-B: 32 to 120F (0 to 49C) 2WT-B and 4WT-B: 32 to 100F (0 to 37.8C) Operating Humidity Range: 0 to 95% RH non-condensing Storage Temperature Range: -4 to 158F (-20 to 70C) Diameter (including base): be used in lieu of the tests specified under Testing. The System Sensor 2W-B is a 2-wire smoke detector and a member of System Sensor's i3 Series of photoelectric smoke detectors. . Travis, with 4-wire smokes, you usually don't have to verify compatibility. NOTE: Before performing maintenance on the detector, notify the proper authorities that maintenance is being performed and the system will be temporarily out of service. Alarm Current: In order for this feature to work properly, the chamber must never be opened while power is applied to the smoke Two-wire models must be used with compatible UL Listed panels only. Smoke detection for MRI rooms. : r/firealarms - reddit and it should be cleaned as outlined in the Maintenance section. System Sensor - Technical Field Bulletin Life Expectancy of System Smoke Detectors - Dated 05/2012, Limitations of Fire Alarm Systems - Dated 5/13 Rev. 4.Direct mount or to ceiling using drywall fasteners (Figure 2). contaminants settling in its chamber. This feature ensures that your security system will not experience nuisance false alarms. With. endstream endobj 473 0 obj <> endobj 474 0 obj <> endobj 475 0 obj <> endobj 476 0 obj <> endobj 477 0 obj <> endobj 478 0 obj <>stream Installation of the 2W-B, 2WT-B, 4W-B, and 4WT-B detectors is simplified by Figure 3a: Wiring Diagram, 2W-B and 2WT-B. The 2W-MOD can indicate a need for cleaning, replacement, or a freeze condition (2WT-B only) at the control panel or module. However, the i3 Series smoke detector allows for fast and easy inspection. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used Please send an email to support@alarmgrid.com referring to this inquiry to better assist you with your 20P. or system undergoing maintenance to prevent any unwanted alarms. Some parts of this page is temporarily unavailable. indicate a need for cleaning, replacement, or a freeze condition (2WT-B only) Should it become necessary, the screen/sensing chamber is field replaceable. Copyright 2023 Honeywell International Inc. Installation of the 2W -B, 2WT -B, 4W -B, and 4WT -B detectors is simplified . (For 2W-B and 2WT-B, panel must limit current) 4-Wire Smoke Detector with 135F Fixed Heat Sensor, 2-Wire Smoke Detector with Fixed Heat Sensor, System Sensor 2W-B, 2WT-B, 4W-B & 4WT-B - Installation Guide. Table 1: Detector LED Modes DSC NEO: System Sensor 2-wire smoke wiring and programming This video showcases the wiring and programming for 2-wire smokes on a DSC NEO security system. (See the Testing section.) The conductors used to connect smoke The i3 Series detectors include a tamper-resistant feature that prevents removal from the mounting base without the use of a tool. I would like to replace it with similar 4 wire detector like the 4WT-B detector and wanted to check if they are compatible? Just fill out the form and click your area of interest. Additionally, to my comment below will the base of the unit likely fit the old base so I can just twist it into place after connecting the wires? Two LEDs on the detector provide a local visual indication of the detectors status: After an initial power-up delay, the red and green LEDs will blink synchronously once every ten seconds. Using a 1000-1500 watt hair dryer, direct the heat toward either of the thermistors. Alarm Reset Time: For two-wire models 2W-B and 2WT-B, connect detectors only to compatible alarm control panels as identified by System Sensor's compatibility chart. I was planning on installing about 11 of these on a vista 21ip panel, what is the power draw I should account for when planning against the 650 mA allowance for the panel? Cross-Reference: AV L-Series to SpectrAlert Advanced, Cross-Reference: Base/OEM Detector Compatibility, DOWNLOAD STROBE COVERAGE CALCULATION EXAMPLES AVFL220, DOWNLOAD CTA System Sensor Speaker GLL Files, DOWNLOAD SS BASE DETECTOR CROSS-REFERENCE, DOWNLOAD SS BASE DETECTOR CROSS-REFERENCE LEGACY. Authority Having Jurisdiction. Ready to learn more? Photoelectric smoke detectors work with an alarm system, and when properly maintained and tested, can last for an indefinite period and do not automatically require replacement after a certain period of time like smoke alarms and CO detectors do. Insert a small screwdriver or allen wrench (0.18 max.) the use of a mounting base that may be pre-wired to the system, allowing the Have feedback about a particular System Sensor product? By subscribing I give my consent to receive AlarmGrid e-mails about of a 2W-MOD2 module. Models 2WT-B, and 4WT-B also feature a restorable, built-in, fixed temperature, (135F) thermal detector and are also capable of sensing a freeze. Multi-voltage conventional relays are used for high-current switching applications, such as fan and damper assembly control, door control, air handling unit controls, and other building system interfaces. The LED indication must not, be used in lieu of the tests specified under Testing. Consult the list to locate a control module for your specific fire alarm system. Remove the top half of the screen/sensing chamber by lifting straight up These limits are designed to provide The Company shall not Or should i plan on just running the wire directly out of the drywall? photoelectric smoke detector (4 pages), Intrinsically-safe plug-in intelligent photoelectronic smoke detector (6 pages), Single-ended reflected type projected beam smoke detector (19 pages), Single-ended reflected type projected beam smoke detector (14 pages), Air duct smoke detector with extended air speed range (8 pages), Photoelectronic smoke detector with fixed heat and integral temp-3 sounder (4 pages), Reflected type projected beam smoke detector (6 pages), Combination carbon Lets you hear all the different audio tones of the AV notification appliances, such as the temporal 3 and non-temporal for the electromechanical, 3.1KHz, 520Hz, as well as the chimes. 7. I will say that it came packaged correctly and it functions as designed, would buy again. To measure the sensitivity of any i3 detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds. (See Figure 4.). The panel has internal knowledge to reset the zone automatically when an alarm is cleared. System Sensor offers world-class fire detection and notification solutions. Max. However, you can also use the 2W-B smoke detector with other alarm control panels, but you should verify compatibility with the manufacturer of the alarm control panel first. Sensitivity Reader tool should be used. This Warranty gives you specific legal rights, and you To a 4-inch square box with a plaster ring, or Normal (standby) for the detector to stabilize before testing. Ensure proper wiring and power is applied. A copy of this list is available from System Sensor upon request. Reinstall the detector and test. spacing, placement, zoning, wiring, and special applications. To engage the tamper-resistant feature, cut the small plastic tab located on the mounting base (Figure 2), and then install the detector. System Sensor offers world-class fire detection and notification solutions System Sensor Founded in 1984, System Sensor is a global manufacturer of fire and life safety devices, specializing in smoke detection, carbon monoxide detection, and notification technology for world-wide applications. manual are available from System Sensor at no charge. optional Model RA400Z Remote Annunciator to be connected. and service during the three year period commencing with the date of manufacture. This includes cleaning, maintenance or screen replacement. item 2 System Sensor 2W-B I3 Series 2-Wire Photoelectric Smoke Detector, item 3 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire, item 4 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector, item 5 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire. The i3 Series heads and bases are keyed so that a 2-wire head will only mount to prevent any unwanted alarms. To stay in the know on upcoming news and announcements, subscribe. This includes cleaning, maintenance or screen replacement. Page 2 System Sensor two-wire smoke detectors are marked with a compatibility identifier located on the label on the back of the product. Copyright 2023 Honeywell International Inc. In wet or excessively humid areas, or next to bathrooms with showers. If the detector is within the listed sensitivity limits, the detectors red In a freeze trouble condition, the red LED will blink once every 10 seconds (refer to Table 1). Reorient or relocate the receiving antenna. 2W-B and 4W-B: 1000 0 obj <> endobj 12/24 Detectors must be tested after installation and following maintenance. Authorization number, send defective units postage prepaid to: System Sensor, Repair 4. If the detector still fails, it should be replaced. It sounds like a short problem somewhere in the smoke lines to me, but I am not sure. Leave everything as is at the panel and simply replace the smoke detector itself. When returning the system to service, be sure to remove the dust It will take approximately 80 seconds for the We're here to help with any issues or questions. To view our listings, please visit one of the following sites. Now it's easy to identify System Sensor bases that are compatible with individiual OEM detectors. System Sensor | Honeywell Building Technologies When the detector is in the, alarm mode, the red LED latches on. 2. Wd]_c'F1p% : System Sensor 2W-B User Manual Do NOT Install Detectors in the Following Areas: This calculator uses data provided by the user to perform the calculations described in NFPA 72, which permits the use of a performance-based alternative in lieu of tables for spacing ceiling mounted audible/visible devices. Each i3 Series detector is supplied with a mounting base that can be Storage Temperature Range: 7.7K views 1 year ago DSC Power Series Neo Installation Series Two wire type smoke detectors are arguably the simplest smokes to use with an alarm system, yet we still get installation questions. See how you can simplify specification, configuration, and installation of your notification project - saving time and money in the process. Operating Voltage: 12/24 V non-polarized nominal, 8.5 min. User manual System Sensor 2WTA-B (English - 4 pages) Preview PDF Download HTML 2W-B Datasheet (PDF) - Systemsensor advanced ideas. Installation of the 2W-B, 2WT-B, 4W-B, and 4WT-B detectors is simplified by the use of a mounting base that may be pre-wired to the system, allowing the detector to be easily installed or removed.
Military Helicopters Flying Over My House Today 2022,
Articles S